1213

Table 1. SYMAPI_AEVENT2_UID_THRESH_TDEV_USED
1213 SYMAPI_AEVENT2_UID_THRESH_TDEV_USED
Category status
Component Device number, for example:
Device=1234
Severity Determined by Threshold values. See below.
Message Thin Device is now <NN> percent used.
Table 2. Unisphere policy name
Unisphere policy name Thin Device Usage
Action type Alert

This is a Threshold event that reflects the amount (as a percentage) of a Thin Device that has been written to.

Unless threshold values are supplied with the registration, the following defaults are used to derive an event severity:

If value is 100% — Fatal

If value is >= 80% — Critical

If value is >= 70% — Major

If value is >= 65% — Minor

If value is >= 60% — Warning

Otherwise — Normal

Notes

  • Events are only delivered at multiples of 5% ... for <NN> equal to 5%, 10%, 15%, ... , 75%, 80%, 85%, 90%, 95% and 100%.
  • Threshold events are only delivered when the severity, as determined by threshold values, changes.